עם ישראל חי
Israel delivery includedPriced BAC Water and NAD+ in ILS · estimated 1–2 business-day delivery (Sunday–Thursday)Choose a product →
Laboratory research materials only · Research purchaser verification required
My account ↗
Israel · ILS checkout for priced BAC Water and NAD+ sizes only · other materials by inquiry

Peptide COA walkthrough: real HPLC reports, content and identity

Read the original certificate for the actual compound, size and lot. Then separate chromatographic purity, identity and measured content. This walkthrough uses three real issuer-hosted reports and explicitly labels missing tests and illustrative arithmetic.

Three original reports, four separate component results

The issuer-hosted records below were accessible and their displayed fields checked on October 21, 2026. This verifies what those pages say, not sample custody, laboratory accreditation or independent authenticity. Reports were analyzed/issued September 24, 2026. Values describe submitted samples, not every vial in a lot.

Issuer-reported results; open the complete original
Report / lotMaterial and labelHPLC area purity / retention timeMeasured content
RSK-20260916-89A2-01 · SEMA5-RESET/KAR-09142026Semaglutide · 5 mg96.95% · 7.157 min5.18 mg/vial
RSK-20260916-A7H4-01 · SEMA15-RESET/KAR-09142026Semaglutide · 15 mg99.20% · 7.198 min15.79 mg/vial
RSK-20260916-62MC-01 · WOLVBB20-RESET/KAR-09142026BPC-157 · 10 mg99.36% · 6.784 min11.41 mg/vial
RSK-20260916-62MC-01 · WOLVBB20-RESET/KAR-09142026TB-500 · 10 mg99.99% · 5.538 min10.92 mg/vial

Report reading is not a pass/fail rubber stamp: the appearance row pairs “White lyophilized powder” with “Clear, colorless” while marked conforming. This may involve sample preparation, but that context is not established here. Ask the issuer to clarify the sample state and specification; do not silently reconcile the mismatch.

Annotated companion to the original chromatogram

Open report RSK-20260916-89A2-01 above and its “Chromatogram & Sample Reference” panel beside this guide. The issuer restricts reproduction, so we link to the complete report rather than crop, redraw or relabel its analytical image. The annotations below concern the report’s printed fields; we have not re-integrated raw instrument data.

Four annotations to use with the original report
MarkerFind in originalInterpretation / limitation
A · sampleReport reference and client lotMatch SEMA5-RESET/KAR-09142026; report ID is not the lot.
B · timeMain-peak retention time: 7.157 minA method-dependent location, not proof of identity by itself. Compare the reference under the same method.
C · area96.95% of total integrated peak areaPeak area is integrated signal, not peak height or mass fraction of all powder. Co-elution and detection limits matter.
D · identityRT + UV versus referenceThis report names HPLC-DAD and retention/UV comparison, not an MS identity result. Missing MS remains unknown.

To assess the trace beyond these printed fields, request the acquisition method, integration table and rules, reference material, wavelength, resolution of nearby peaks, blank/system-suitability results, and raw data if available. A neat image cannot establish these missing details. No new testing or chromatogram was generated for this walkthrough.

Two calculations that answer different questions

HPLC area % = 100 × target-peak area ÷ sum of included integrated peak areas. Illustrative arithmetic only: 9,695 area units ÷ 10,000 × 100 = 96.95%. These areas are invented teaching numbers, NOT the laboratory’s raw peak areas. Detector response, integration thresholds and unresolved components limit interpretation; water and counterions may not appear in that UV denominator.

A separate content calculation uses the reported 5.18 mg and 5 mg label: 5.18 ÷ 5 × 100 = 103.6% of label claim. It is not a purity calculation. A calibrated content assay requires its own reference standard, preparation and recovery/uncertainty assessment. Never multiply the label by HPLC area % and present the result as measured net peptide content.

What mass spectrometry adds—and what it does not

MS measures mass-to-charge signals. Charge-state assignment and deconvolution can support a molecular-mass match to a specified form; MS/MS fragments can add sequence information. An expected mass alone does not fully resolve isomers, sequence identity or every impurity. LC-MS purity and UV area purity have different response biases and are not interchangeable percentages.

The three examples do not establish sterility, endotoxin, residual solvents, metals or manufacturing compliance. The issuer states it is not FDA-registered and does not perform GMP release testing. Accreditation, if claimed elsewhere, must be checked against the laboratory’s actual accredited scope. “Not reported” means unknown, not passed.

Primary sources and verification records

Illustrative laboratory vials forming the Locked Aminos wordmark
Illustration only, not evidence of a tested batch.

Match the sample before the percentage

Match the full compound, chemical form, component amounts, vial label and lot. The report ID identifies a document; the client lot identifies the submitted material. Another lot or size is not a substitute.

Verify the issuer and scope

Open the original issuer record and check its reference, dates, methods and limitations. Reachability alone is not independent authentication, accreditation or chain-of-custody verification.

Keep blend components separate

A blend requires the identity and reported amount of each component. Do not combine two component purity percentages into an unsupported overall purity claim.

Submitting company is not the testing laboratory

Locked Aminos and Reset Supply share the owner Vegas Research Peptides LLC. Reset Supply or KARNELI can appear in client-supplied report fields. A client name does not identify the laboratory or establish a match to your vial.

Sources and review scope

Sources explain terminology and evidence limits. They are not commercial endorsements or approvals of catalog products. Check the original source for updates.